Borg RPE and Heart Rate: From Exercise Research to FCE Interpretation

Borg RPE and Heart Rate: From Exercise Research to FCE Interpretation

By Kevin Cairns, Metriks Education Inc.

A Rating of Perceived Exertion (RPE) records how hard a person feels they are working. During a Functional Capacity Evaluation (FCE), it gives the assessor information that cannot be obtained simply by recording the weight lifted, the distance walked or the heart rate reached. Comparing the person’s reported exertion with their measured response can also contribute to the assessment of consistency.

The familiar relationship Borg RPE × 10 ≈ heart rate explains why the original scale runs from 6 to 20. It provides a useful comparison, but its interpretation depends on understanding what Gunnar Borg developed, what subsequent research demonstrated, and what the person was doing when the measurements were taken.

What Was Gunnar Borg Trying to Measure?

Borg’s work on perceived exertion emerged in the 1960s from psychophysics: the study of how people perceive physical stimuli. His practical problem was straightforward. We can measure an external workload, but that does not tell us how demanding the work feels to the person performing it.

Two people can cycle against the same resistance or walk at the same speed and experience different levels of exertion. A useful assessment therefore needs a way to record the person’s experience alongside physiological measurements and observed performance.

In his 1982 paper, Borg described perceived exertion ratings as complementary information for understanding physical performance and work capacity, with applications in medicine, human factors and sport. His objective was to make subjective experience measurable in a structured way. [1,2]

That purpose remains relevant to FCE practice. The assessor needs to know both what the person performed and how demanding that performance felt.

Why Does the Borg Scale Run From 6 to 20?

The Borg 6–20 scale was constructed so that ratings would increase approximately linearly with heart rate and oxygen consumption during steady-state exercise. Its numerical range reflects the approximate relationship between ratings of 6–20 and heart rates of 60–200 beats per minute. [1,2]

The familiar calculation is:

Approximate heart-rate comparison = RPE × 10

Borg 6–20 rating RPE × 10
9 90 bpm
11 110 bpm
13 130 bpm
15 150 bpm
17 170 bpm

These examples explain the scale’s numerical design. They are not individualized heart-rate targets or exact predictions. A rating of 13 does not require every person to have a heart rate of 130 bpm, and a rating of 20 does not mean that every person can or should reach 200 bpm.

An RPE rating describes perceived exertion. The monitor measures heart rate. Their relationship gives the assessor another question to investigate: Does the reported exertion make sense alongside the measured response and the task performed?

What Has the Research Found?

Perceived exertion can track changes in workload

In a 1976 study, Stamford tested 14 sedentary women during walking, jogging, cycling and stepping under different workload sequences. RPE responses were reproducible and related strongly to heart rate and work intensity. This supported using the scale to monitor exertion across repeated exercise tasks. The small sample and controlled conditions also define the limits of that finding. [3]

A much larger study by Scherr and colleagues examined 2,560 participants during incremental treadmill or cycle tests. Heart rate, blood lactate and Borg 6–20 ratings were recorded at the end of each workload. RPE correlated with heart rate at r = 0.74 and blood lactate at r = 0.83. [4]

These findings support collecting RPE alongside physiological measurements. However, correlation describes how measurements vary together. It does not establish that multiplying every individual rating by 10 will reproduce that person’s measured heart rate.

The strength of the relationship varies

Chen, Fan and Moe’s 2002 meta-analysis found a weighted mean correlation of 0.62 between RPE and heart rate. Fitness, exercise type, protocol and the way RPE was obtained helped explain variation between studies. The authors concluded that the relationship was less consistently strong than sometimes assumed. [5]

For the assessor, the implication is practical: the comparison has a research basis, but its meaning depends on how it is applied. A relationship demonstrated across progressive exercise workloads does not automatically establish the accuracy of a single reading after a different task.

Larger, newer studies still emphasize context

A 2024 study analyzed exercise-test data from 6,311 participants. It examined RPE at blood-lactate reference points and found that individual and test characteristics affected interpretation, particularly at lower intensities. These included age, sex, exercise modality, fitness and test duration. The authors also explicitly cautioned against transferring their treadmill and cycling results to resistance exercise. [6]

This is relevant to an FCE because the assessment may combine walking, lifting, sustained postures and brief force-production tasks. Those activities do not impose identical physiological demands.

How Is Borg RPE Used Outside an FCE?

Exercise testing and aerobic training

During progressive treadmill or cycle testing, RPE helps describe the person’s response as workload increases. In training, it can help the person regulate intensity and communicate how demanding a prescribed workload feels. Scherr’s research supports these uses while also demonstrating that RPE is associated with, rather than identical to, physiological measurements. [4]

Cardiac rehabilitation

Cardiac rehabilitation uses RPE alongside clinical findings and physiological monitoring to guide exercise intensity. A European Association of Preventive Cardiology position statement supports combining perceived exertion with objective measures and discusses its usefulness when heart rate is unavailable or difficult to interpret. [7]

This is particularly relevant when medication alters the heart-rate response. The exertion rating may remain useful even when the simple RPE-to-heart-rate comparison is unsuitable.

Sports training load

Foster and colleagues studied session RPE as a way to quantify training load during cycling and basketball. That approach uses an overall session rating with exercise duration to describe the training session. [8]

A session rating and a rating taken immediately after one FCE task answer different questions. Their scale, timing and intended interpretation need to be identified before using the number.

Ergonomics and occupational work

Borg also described applications in physical work and ergonomics, where the worker’s perception contributes information about the demands of a task. [9]

Workplace evidence illustrates why the context matters. A study of blue-collar workers performing lifting tasks found weak associations between perceived exertion and several objective workload measures. It used the Borg CR10 scale and workday measurements, so it should not be treated as a direct test of the 6–20 comparison used after an FCE task. It does show that a finding from an exercise laboratory cannot simply be assumed to apply unchanged to a working day. [10]

The Borg 6–20 Scale and CR10 Scale Are Different

“Borg scale” can refer to more than one instrument. The original RPE scale runs from 6 to 20. Borg also developed the category-ratio CR10 scale, which has different scaling properties and applications. [1,2,9]

The RPE × 10 ≈ heart rate comparison discussed here applies to the 6–20 scale. A CR10 rating of 7 must not be entered as a Borg 6–20 rating of 7 for this calculation.

Likewise, a pain score is not an exertion score. When collecting RPE during an FCE, make clear which experience the person is rating and record pain separately.

How Do We Use RPE During an FCE?

Collecting an RPE after a task is a clinical choice. When it is recorded alongside heart rate, it provides one of the FCE’s validity cross-checks.

There is support for this comparison in FCE education. The Academy of Orthopaedic Physical Therapy’s Functional Capacity Evaluation and Disability Determination monograph recommends monitoring perceived exertion alongside physiological responses and describes comparing activity heart rate with ten times the Borg 6–20 rating during incremental workloads. [11]

The 2018 Current Concepts in Functional Capacity Evaluation: A Best Practices Guideline also includes physiological and psychophysical monitoring. It recognizes that medication or factors such as a pacemaker may alter heart-rate interpretation and discusses other monitoring measures, including perceived exertion. [12]

Within the FCE, the comparison adds to the information obtained from task performance, symptoms, movement quality, observed effort and consistency across activities. It is one part of the assessor’s interpretation.

How the Metriks software calculates the result

The Metriks calculation is:

Difference = (Borg 6–20 RPE × 10) − measured heart rate

Calculated difference Software result
40 or less Valid
Greater than 40 Invalid
RPE or heart rate missing No validity result generated

For example, an RPE of 17 with a heart rate of 120 bpm produces:

(17 × 10) − 120 = 50

The software marks that comparison Invalid because 50 exceeds the threshold of 40. It flags reported exertion that is high relative to the measured heart rate.

The direction of the calculation matters. It is not an absolute difference and it is not a ±40 bpm range.

RPE Measured HR Calculation Software result
13 130 bpm 130 − 130 = 0 Valid
17 130 bpm 170 − 130 = 40 Valid
17 120 bpm 170 − 120 = 50 Invalid
11 160 bpm 110 − 160 = −50 Valid

The final example passes this particular rule because −50 is less than 40. It does not establish that the person’s heart-rate response is clinically appropriate. Physiological safety and interpretation still require the assessor’s attention.

What does “Invalid” mean here?

It means that this RPE–heart-rate comparison exceeded the software’s threshold. It does not, by itself, establish inadequate effort, intentional misrepresentation or an invalid FCE.

The 40-point threshold is a Metriks software decision rule. The research supporting the Borg scale and its relationship with physiological workload should be distinguished from validation of this exact cutoff for classifying FCE performance.

An applicable result contributes to the overall validity percentage alongside other checks. That percentage summarizes the classifications included in the assessment; it is not a measured probability that the person is truthful.

What Should the Assessor Check When RPE and Heart Rate Differ?

Confirm the scale and the question

Check that the person used the 6–20 scale and understood that the question concerned exertion. Clarify whether the response described overall effort, a particular muscle group, pain or another symptom. Do not assume that an unexpectedly high number has only one explanation.

Match the measurements to the same task period

Record RPE and heart rate at a consistent, task-appropriate time. A rating describing the end of a demanding task should not be paired without explanation with a heart rate recorded after recovery. Scherr’s study, for example, collected the measures together at the end of each workload. [4]

Check the heart-rate signal and document when the reading was taken. A comparison is only as interpretable as the measurements entered.

Consider the type of task

A brief static push, sustained overhead reach and progressive walking test place different demands on the person. Local muscular exertion can be substantial without reproducing the whole-body cardiovascular response seen during aerobic exercise.

In a small study of 12 young men, the association between Borg 6–20 ratings and heart rate was weaker during static and partially dynamic tasks than during dynamic exercise. This supports task-specific interpretation, although the small, restricted sample limits generalization. [13]

For FCE practice, this means examining the actual task and the observed response before using a discrepancy to support a broader conclusion about effort.

Review medication and relevant history

Beta-blockers can lower exercise heart rate and alter its relationship with perceived exertion. In a randomized crossover study of 16 healthy participants, metoprolol reduced exercise heart rate while RPE remained useful in describing relative exercise intensity. The population and experimental design should be kept in mind when applying the findings clinically. [14]

When medication affects heart-rate interpretation, continue monitoring heart rate but exclude this cross-check from the validity assessment. Document the reason for exclusion. RPE can still help describe the person’s response, and appropriate safety monitoring continues. [11,12]

Compare the finding with the rest of the assessment

Review performance across related tasks, changes with increasing workload, observed mechanics, symptoms and other consistency findings. If the discrepancy remains unexplained, report it accurately and explain how much weight it carries in the overall interpretation.

This approach fits an FCE built around the person and the assessment purpose: collect the information needed to answer the referral questions, then explain how the findings support the conclusions.

How Can This Be Written in an FCE Report?

The report should identify the measurements and the interpretation. For example:

Following the task, the evaluee reported exertion of 17 on the Borg 6–20 scale. Heart rate recorded at task completion was 120 bpm. The calculated difference was 50, exceeding the Metriks threshold of 40 and generating an Invalid result for this comparison. This finding was considered alongside task performance, observed mechanics, symptoms and the other consistency measures.

Where medication makes the comparison unsuitable:

Heart rate and perceived exertion were monitored during testing. The RPE–heart-rate validity comparison was excluded because medication affected interpretation of the heart-rate response.

These statements distinguish the recorded finding, the software classification and the assessor’s broader interpretation.

Frequently Asked Questions

Does an RPE of 13 mean heart rate must be 130 bpm?

No. Multiplying the Borg 6–20 rating by 10 provides an approximate comparison. It does not predict every individual’s heart rate precisely. Consider the person, task and measurement conditions.

Must I collect RPE after every FCE task?

Collecting RPE after a task is a clinical choice. When using the Metriks comparison, both the Borg 6–20 rating and corresponding heart rate must be present. A missing value produces no validity result; it is not automatically an Invalid result.

Does an Invalid result prove poor effort?

No. It flags a discrepancy under this software rule. Review the scale, timing, medication, task demands and other findings before interpreting its significance.

Can I use the Borg CR10 scale in this calculation?

No. This calculation uses the Borg 6–20 scale. CR10 has other legitimate applications, but its scores are not interchangeable with 6–20 ratings.

Should I stop monitoring heart rate when the comparison is excluded?

No. Excluding the validity comparison does not remove physiological monitoring. Continue to interpret heart rate and other relevant responses in the context of the person’s history, medication and clinical presentation.

Applying the Research in FCE Practice

Borg’s work gave clinicians a structured way to record how demanding physical work feels. In an FCE, that information helps explain the person’s response to the task and can contribute to consistency assessment when compared with heart rate.

Use the correct scale, pair the measurements appropriately, apply the software rule accurately and explain the result within the full assessment.

Explore Metriks FCE certification and Metriks FCE software.

Related reading

References

  1. Borg GA. Psychophysical bases of perceived exertion. Medicine & Science in Sports & Exercise. 1982;14(5):377–381. PubMed.
  2. BorgPerception. Borg RPE Scale and Borg CR Scales: descriptions of scale design and applications. Official scale information.
  3. Stamford BA. Validity and reliability of subjective ratings of perceived exertion during work. Ergonomics. 1976;19(1):53–60. PubMed.
  4. Scherr J, et al. Associations between Borg’s rating of perceived exertion and physiological measures of exercise intensity. European Journal of Applied Physiology. 2013;113:147–155. PubMed.
  5. Chen MJ, Fan X, Moe ST. Criterion-related validity of the Borg ratings of perceived exertion scale in healthy individuals: a meta-analysis. Journal of Sports Sciences. 2002;20(11):873–899. PubMed.
  6. Rating of Perceived Exertion: A Large Cross-Sectional Study Defining Intensity Levels for Individual Physical Activity Recommendations. Sports Medicine – Open. 2024. DOI: 10.1186/s40798-024-00729-1. Full text.
  7. Exercise intensity assessment and prescription in cardiovascular rehabilitation and beyond: why and how. Position statement from the Secondary Prevention and Rehabilitation Section of the European Association of Preventive Cardiology. European Journal of Preventive Cardiology. 2022;29(1):230–245. Journal.
  8. Foster C, et al. A new approach to monitoring exercise training. Journal of Strength and Conditioning Research. 2001;15(1):109–115. PubMed.
  9. Borg G. Psychophysical scaling with applications in physical work and the perception of exertion. Scandinavian Journal of Work, Environment & Health. 1990;16 Suppl 1:55–58. Journal.
  10. Is Borg’s perceived exertion scale a useful indicator of muscular and cardiovascular load in blue-collar workers with lifting tasks? A cross-sectional workplace study. European Journal of Applied Physiology. 2014;114:425–434. PubMed.
  11. MacMasters W, Allison S, Wickstrom R, McMenamin P. Functional Capacity Evaluation and Disability Determination. Academy of Orthopaedic Physical Therapy, Independent Study Course 32.5.3. 2022. See printed pp. 40 and 58. Supplied project source.
  12. Current Concepts in Functional Capacity Evaluation: A Best Practices Guideline. Adopted April 30, 2018. Physiological and psychophysical monitoring sections. Supplied project source.
  13. Chen YL, Chen CC, Hsia PY, Lin SK. Relationships of Borg’s RPE 6–20 scale and heart rate in dynamic and static exercises among a sample of young Taiwanese men. Perceptual and Motor Skills. 2013;117(3):971–982. PubMed.
  14. Mitchell BL, et al. Physiological and Perceived Exertion Responses during Exercise: Effect of β-blockade. Medicine & Science in Sports & Exercise. 2019;51(4):782–791. PubMed.
Back to blog